AFT140-II
FYI
Blue
1PCS
China
By TT or LC
Availability: | |
---|---|
APPLICATION:
EN 149 2001 a1 2009 Automatic Particulate Filter Efficiency PFE Tester AFT140-II ,
it is the good solution for testing particulate respirator filters, disposable filtering face pieces, as a wide assortment of filter media .
The built-in capability to test with salt and oil means that just one unit is need to test your product to
US 42 CFR part 84, EN 143.
RELATED STANDARDS:
STANDARDS | GB2626-2006-6.3 | US 42 CFR part 84 | EN 143, EN149, EN 14387 |
Note: this automated filter tester can conform to but not limit to the standards above, for more standards conformance, please contact us.
FEATURES:
1. There are 2EA Aerosol Generators in one unit. One is for Salt testing, the NaCl liquid concentration is 2%. Aerosol rate complies to standard. Counter median diameter: 0.075±0.02μm,
Particle size distribution of Geometric standard deviation is less than 1.86.The other is for Oil testing.
You can select DOP, DEHS, PAO, Parffin Oil, etc.
2. There are 2EA Photometers, Aerosol concentration test range: 0.001-100mg/m3.
Item | AFT-140-II |
Product name | Automated Filter Tester |
Test flow | 30~95L/min |
Test area | 100cm2 |
Flow rate accuracy | ±3% |
Resistance accuracy | 1Pa |
Test repeatability of residual | ≤±10% |
Power supply | AC220V, 50 or 60 Hz |
Dimension | 750mm*700mm*1500mm |
Resistance range | 0~125Pa and 0~500Pa are optional |
Aerosol | NaCl, DEHS, Paraffin oil, etc. |
MOQ | 1 set |
Product Keywords | Mask testing instrument,Inhalation and exhalation testing,Filter or Filtration efficiency tester |
3. The filter tester not only can test efficiency and resistance, but also can apply to test particulate respirator filters at loading.
4. Structure Design and famous brand Aerosol photometer
Special Modular with Split-type and it is easy to change. It is easy to check and clear inside of the machine.
The line layout is beautiful and elegant. The machine is made of cold rolled steel sheet with Plastic spraying
5. PC control system, more efficient and reliable, achieves a variety of functions, such as control, detection, calculation and data display.
6. English – Chinese Software:
7. Menu type operating mode and large LCD display with English – Chinese software,
and it is easy to switch.
KEY SPECIFICATION:
Air flow rate | 20~100L/min |
Efficiency | 0~99.999% |
Resistance | 0~1,000Pa |
Test area | 100m2 |
Power supply | AC220V, 50Hz |
STANDARD CONFIGURATION:
No. | Item | Quantity |
1. | Main machine | 1 set |
2. | Industrial PC | 1 set |
3. | Software | 1pcs |
4. | Aerosol photometer | 2 (TSI BRAND ) |
5. | Neutralizer | 1 (Built–in ) |
6. | Micro differential gauge (France brand KIMO) | 2 pcs (Built–in) |
7. | Orifice flowmeter | 1 pcs |
8. | Heater | 1pcs |
9. | Mask test fixture | 1 set |
10. | Data acquisition card | 16-bit 8-channel (Built–in) |
11. | Flow measuring nozzle | D8 |
12. | calibration filter paper | 100pcs |
APPLICATION:
EN 149 2001 a1 2009 Automatic Particulate Filter Efficiency PFE Tester AFT140-II ,
it is the good solution for testing particulate respirator filters, disposable filtering face pieces, as a wide assortment of filter media .
The built-in capability to test with salt and oil means that just one unit is need to test your product to
US 42 CFR part 84, EN 143.
RELATED STANDARDS:
STANDARDS | GB2626-2006-6.3 | US 42 CFR part 84 | EN 143, EN149, EN 14387 |
Note: this automated filter tester can conform to but not limit to the standards above, for more standards conformance, please contact us.
FEATURES:
1. There are 2EA Aerosol Generators in one unit. One is for Salt testing, the NaCl liquid concentration is 2%. Aerosol rate complies to standard. Counter median diameter: 0.075±0.02μm,
Particle size distribution of Geometric standard deviation is less than 1.86.The other is for Oil testing.
You can select DOP, DEHS, PAO, Parffin Oil, etc.
2. There are 2EA Photometers, Aerosol concentration test range: 0.001-100mg/m3.
Item | AFT-140-II |
Product name | Automated Filter Tester |
Test flow | 30~95L/min |
Test area | 100cm2 |
Flow rate accuracy | ±3% |
Resistance accuracy | 1Pa |
Test repeatability of residual | ≤±10% |
Power supply | AC220V, 50 or 60 Hz |
Dimension | 750mm*700mm*1500mm |
Resistance range | 0~125Pa and 0~500Pa are optional |
Aerosol | NaCl, DEHS, Paraffin oil, etc. |
MOQ | 1 set |
Product Keywords | Mask testing instrument,Inhalation and exhalation testing,Filter or Filtration efficiency tester |
3. The filter tester not only can test efficiency and resistance, but also can apply to test particulate respirator filters at loading.
4. Structure Design and famous brand Aerosol photometer
Special Modular with Split-type and it is easy to change. It is easy to check and clear inside of the machine.
The line layout is beautiful and elegant. The machine is made of cold rolled steel sheet with Plastic spraying
5. PC control system, more efficient and reliable, achieves a variety of functions, such as control, detection, calculation and data display.
6. English – Chinese Software:
7. Menu type operating mode and large LCD display with English – Chinese software,
and it is easy to switch.
KEY SPECIFICATION:
Air flow rate | 20~100L/min |
Efficiency | 0~99.999% |
Resistance | 0~1,000Pa |
Test area | 100m2 |
Power supply | AC220V, 50Hz |
STANDARD CONFIGURATION:
No. | Item | Quantity |
1. | Main machine | 1 set |
2. | Industrial PC | 1 set |
3. | Software | 1pcs |
4. | Aerosol photometer | 2 (TSI BRAND ) |
5. | Neutralizer | 1 (Built–in ) |
6. | Micro differential gauge (France brand KIMO) | 2 pcs (Built–in) |
7. | Orifice flowmeter | 1 pcs |
8. | Heater | 1pcs |
9. | Mask test fixture | 1 set |
10. | Data acquisition card | 16-bit 8-channel (Built–in) |
11. | Flow measuring nozzle | D8 |
12. | calibration filter paper | 100pcs |