DW1380
FYI
White and black
1PCS
China
By TT or LC
Availability: | |
---|---|
APPLICATION:
ISO 12958 In-plane Water Flow Rate Test Apparatus DW1380 for Geosynthetics is applied to determine
the in-plane flow rate per unit width and hydraulic transmissivity within the manufactured plane of geosynthetics under varying normal compressive stresses and standard hydraulic gradient using a constant head.
Related Standards:
STANDARDS | BS EN ISO 12958-2010 | GB/T 17633-1998 |
ASTM D4716-2007 | SL/T 235-9-2012 |
Note: this tester can conform to but not limit to all the standards above, for more standards conformance, please contact us.
FEATURES OF Water Flow Rate Test Apparatus:
1.Conform to different standards, such as GB/T 17633, ASTM D4716 and BS EN ISO 12958;
2.Adjustable pneumatic pressure of 0~600Kpa;
3.Elevating screw rod to manually and continuously adjust head difference up to 400mm with water-level scale display.
KEY SPECIFICATION:
Platen size | 305×305mm (L×W) |
Test specimen thickness | ≤50mm |
Thickness of rubber sheet | 10, 15, 20, 25mm |
Normal pressure | 0~600Kpa, adjustable |
Normal pressure accuracy | ±2% |
Normal pressure resolution | 5Kpa |
Range of head loss | 0~400mm, continuously adjustable |
Accuracy of head loss | ±1mm |
Inflow reservoir specification | 805mm in height with the scale of 0~400mm 370mm in width |
Outflow reservoir specification | 165×370mm (H×W) |
Volume of water storage tank | 120 L |
l Height of dam | 100mm |
APPLICATION:
ISO 12958 In-plane Water Flow Rate Test Apparatus DW1380 for Geosynthetics is applied to determine
the in-plane flow rate per unit width and hydraulic transmissivity within the manufactured plane of geosynthetics under varying normal compressive stresses and standard hydraulic gradient using a constant head.
Related Standards:
STANDARDS | BS EN ISO 12958-2010 | GB/T 17633-1998 |
ASTM D4716-2007 | SL/T 235-9-2012 |
Note: this tester can conform to but not limit to all the standards above, for more standards conformance, please contact us.
FEATURES OF Water Flow Rate Test Apparatus:
1.Conform to different standards, such as GB/T 17633, ASTM D4716 and BS EN ISO 12958;
2.Adjustable pneumatic pressure of 0~600Kpa;
3.Elevating screw rod to manually and continuously adjust head difference up to 400mm with water-level scale display.
KEY SPECIFICATION:
Platen size | 305×305mm (L×W) |
Test specimen thickness | ≤50mm |
Thickness of rubber sheet | 10, 15, 20, 25mm |
Normal pressure | 0~600Kpa, adjustable |
Normal pressure accuracy | ±2% |
Normal pressure resolution | 5Kpa |
Range of head loss | 0~400mm, continuously adjustable |
Accuracy of head loss | ±1mm |
Inflow reservoir specification | 805mm in height with the scale of 0~400mm 370mm in width |
Outflow reservoir specification | 165×370mm (H×W) |
Volume of water storage tank | 120 L |
l Height of dam | 100mm |